Illumination safety: LEDs

LEDs are covered by the IEC regulations and special care needs to be taken to ensure that LED based illumination installations will not cause harm to the operator.

LED lighting safety procedures are very similar to the laser safety regulations and are based on the intensity, duration and wavelength of the light produced.

The EU mandates

In accordance with EU machinery mandates, EMC mandates, and low voltage mandates, machines and electronic devices not marked with the CE logo are subject to distribution restrictions within the EU. All LED illumination products and power supplies should conform to corresponding regulations.

Since September 2011 the new classification standard EN62471 (see table) has to be applied to LED illumination.

Risk definition for LEDs
Exempt No photobiological hazard
Group 1 (low risk) No photobiological hazard und normal behavioural limitations
Group 2 (moderate risk) Does not pose a hazard due to aversion response to bright light or thermal discomfort
Group 3 (high risk) Hazardous even for momentary exposure

UV and IR LEDs

In the case of UV and IR LEDs, special precautions should be taken as the human eye does not see these wavelengths and the user cannot see whether an illumination unit is switched on or not. The following guidelines should be observed.

  • Do not look directly at the LEDs while in operation, even for short periods of time.

  • If you are using UV/IR light, wear suitable eye protection.

  • Avoid prolonged UV light exposure to skin, especially if more than one unit is being used simultaneously

  • Attach corresponding warning notes to the machine.

NOTE: It should be remembered that visible LED devices are perfectly safe under normal viewing conditions. In normal use, standard lighting products from our suppliers will be placed at much greater distances than is used to calculate the MPE tests and typical exposure times will also be much shorter.